For a single bathroom being refitted, electric underfloor heating is usually the better choice: it's cheaper and quicker to install, adds very little floor height, and in a small room the higher running cost amounts to a modest sum. Wet (water-based) underfloor heating costs more to install but less to run, so it makes more sense when the bathroom is part of a wider heating project, or you have a heat pump.
How each system works
Electric underfloor heating is a thin mat or loose cable laid on an insulation board, embedded in a levelling compound or tile adhesive, and tiled over. It runs from its own electrical circuit with a thermostat.
Wet underfloor heating circulates warm water from your boiler or heat pump through pipes in the floor -- either set in a screed, or in grooved low-profile boards for retrofits. It connects to your central heating via a manifold and mixing valve.
Electric vs wet at a glance
| Electric | Wet | |
|---|---|---|
| Installation | Simpler and cheaper | More complex; connects to the heating system |
| Floor height added | Minimal -- often around 10mm with insulation board | More, typically 20mm or above even for low-profile retrofit systems |
| Running cost | Higher per hour of use | Lower, especially with a heat pump |
| Warm-up time | Fast | Slower, but holds heat longer |
| Best for | Single bathrooms, en-suites, refits | Whole-house schemes, extensions, new builds |
| Regulations | New circuit is notifiable under Part P | Plumbing to the heating system |
Running costs in a bathroom
Electric heating costs more per hour to run than wet, but a bathroom is a small room and the floor is usually only on for short periods on a timer. In cash terms the difference for one bathroom is often modest, while the installation cost difference is not. Room size, insulation under the heating and how long you run it matter more than the system type. A good insulation board under an electric mat makes a noticeable difference to both warm-up time and cost.
Floor height and the rest of the bathroom
Height is often the deciding factor in a refit. Every millimetre added at the floor affects the door threshold, the toilet and basin pedestal, the bath panel and the shower tray. Electric systems keep the build-up minimal; wet retrofit systems usually need the floor lifted, or a threshold at the door.
Tiles and underfloor heating
- Porcelain and natural stone conduct heat well and are the usual choices.
- The tile adhesive and grout must be rated for underfloor heating -- they need some flexibility to cope with warming and cooling.
- Waterproofing can go over or under the heating depending on the system; follow the manufacturer's order of layers. See bathroom tanking.
- A new screed for wet heating needs time to dry before tiling, which affects the schedule. See how long a bathroom refit takes.
Can underfloor heating replace the towel rail?
It can heat the room, but most people still want a heated towel rail for drying towels. A dual-fuel or electric towel rail alongside electric underfloor heating is a common combination.
Underfloor heating FAQs
Can you put underfloor heating in a shower or wet room?
Yes, with products designed for it. Electric mats are laid under the waterproofing or tile layers as the system requires, and some are approved for use in wet room floors. Keep the heating clear of the drain itself and follow the manufacturer's layout rules.
Does electric underfloor heating need an electrician?
Yes. The mat can be laid as part of the tiling, but the connection needs its own circuit and thermostat, and a new circuit in a bathroom is notifiable under Part P. It should be installed and certified by a qualified electrician.